Home › Equipment › Buying a commercial dishwasher in Georgia
Buying a commercial dishwasher in Georgia
- Pick what you need and give your kitchen's ZIP code.
- Each service goes to the number of local companies you choose, from one to five. We check licenses where the law requires one and email you their names.
- You talk with them and decide. You hire and pay the company directly.
Facts checked 2026-11-15.
A commercial dishwasher has to wash and sanitize, and a Georgia buyer chooses between hot water and chemical sanitizing before anything else. The machine type, rack count and utility hookups follow from that choice.
Kinds, sizes and fuel
ENERGY STAR lists undercounter, single-tank door-type, pot, pan and utensil, and glasswashing machines, and rack and flight-type conveyors, in high or low temperature. Hobart's LXnR undercounter is high temperature, rated 30, 24 and 13 racks an hour on light, normal and heavy soil, at 0.62 gallons a cycle.
Jackson's Conserver XL2 is a chemical-sanitizing door-type rated 82 racks an hour at 1.06 gallons a rack, ETL and cETL listed and ENERGY STAR certified. CMA lists undercounter, upright, scullery and conveyor models, and its EST 44 conveyor is rated 249 racks an hour. Champion lists undercounter, glasswasher, door-type, rack conveyor, flight and pot and pan models.
Makers of dishwashers include CMA, Champion, Hobart and Jackson.
What Georgia checks
A February 2025 revision brought the 2022 FDA Food Code into Georgia's Chapter 511-6-1. For warewashing, Rule .05 expects commercial-grade machines, and a model with an ANSI-accredited certification is deemed to meet the design rules. The warewashing standard is NSF/ANSI 3, and a companion standard, NSF/ANSI 29, covers the detergent and chemical feeders on spray-type machines.
The 2022 Food Code is specific about temperatures. A spray-type hot-water machine needs wash temperatures from 150 to 165 degrees F depending on type, and the final sanitizing rinse is 165 degrees F at minimum for a single temperature stationary rack machine or 180 degrees for the others, with a 194 degree ceiling. Rinse pressure runs between 5 and 30 psi. Chemical machines wash at 120 degrees F or higher and follow rules for concentration and the EPA label. The machine also needs a data plate listing its temperatures, pressure and cycle time, and operators run it to that plate.
County Environmental Health offices review plans for a new or extensively remodeled restaurant, with fixed equipment listed by type and model. The opening a restaurant guide shows where that step falls, and the grease trap guide covers the drain side of a dish station.
UL's guide says some commercial dishwashing appliances must sit under a Type II hood for heat and steam, without naming which ones. Ask the seller and your building department whether the model you want needs a vent hood in your building.
Get prices for this item. One request, and you pick how many sellers quote it.
Get quotesEfficiency and rebates
ENERGY STAR rates idle energy by machine type and temperature class, along with water used in the final rinse. No federal standard for the dishwasher itself turned up in 10 CFR Part 431, but the pre-rinse spray valve at the dish station has one: for valves made on or after January 28, 2019, maximum flow is 1.00, 1.20 or 1.28 gallons a minute depending on spray force.
Georgia Power lists a commercial dishwasher rebate for ENERGY STAR models, excluding low-temperature ones. Each program's rules set who qualifies, so read them on Georgia Power's page before you buy.
What to ask a seller
- Does it sanitize with hot water or chemicals, and does it need a booster heater or a sanitizer supply?
- How many racks an hour does it clean, and how much water per rack?
- What do the data plate and spec sheet say about electrical needs, inlet water temperature and pressure?
- Does it carry the NSF/ANSI 3 mark, and is it ENERGY STAR certified?
- Does this model need a Type II hood or a condensate hood where you are?
- What does the warranty cover? Jackson lists one year parts and labor on the XL2.
Fill out the form once to hear from the local equipment sellers you select, from one up to five.
Other kitchen equipment
Questions
What is the difference between a high temperature and a chemical dishwasher?
A high temperature dishwasher sanitizes with hot water, and a chemical one uses a sanitizer solution. Hot machines need the rinse temperatures the Food Code lists, and chemical machines need a sanitizer supply.
Does a commercial dishwasher need a hood in Georgia?
A commercial dishwasher may need a Type II hood, because UL's guide says some dishwashing appliances do. The guide does not say which, so ask your building department.
Is there an ENERGY STAR commercial dishwasher?
An ENERGY STAR commercial dishwasher exists in undercounter, door-type, conveyor and other types. Georgia Power's page lists a rebate that excludes low-temperature models.
How many racks per hour do I need?
The racks per hour you need depend on your volume, and published ratings run from 13 on a heavy-soil undercounter cycle to 249 on a conveyor. Match the machine to your busiest service.
Sources
- Georgia DPH food service page
- Georgia Rule 511-6-1-.05, equipment
- Georgia Rule 511-6-1-.02, plan review
- FDA Food Code 2022 full text
- NSF food equipment certification overview
- NSF certified food equipment listings, standard 3
- UL, Commercial Cooking Marking and Application Guide
- ENERGY STAR, commercial dishwashers
- 10 CFR 431.266, pre-rinse spray valves
- ENERGY STAR Rebate Finder
- Georgia Power business rebates
- Hobart LXnR undercounter
- CMA Dishmachines
- Champion Industries products