Home › Guides › Commercial kitchen hoods and exhaust in Georgia

Commercial kitchen hoods and exhaust in Georgia

  1. Pick what you need and give your kitchen's ZIP code.
  2. Each service goes to the number of local companies you choose, from one to five. We check licenses where the law requires one and email you their names.
  3. You talk with them and decide. You hire and pay the company directly.
Get connected

Facts checked 2026-11-02.

A new stainless kitchen hood with baffle filters over a cooking line
A new hood over a cooking line.

A commercial kitchen hood in Georgia answers to the state mechanical code, the state fire rules and the health rules at once. Each city and county permit office adds its own checklist on top.

The state mechanical code

The Department of Community Affairs (DCA) sets the state minimum codes. Its memo of December 1, 2025 lists the 2024 International Mechanical Code (IMC) with Georgia amendments as effective on January 1, 2026. Cities and counties apply it when they review and inspect mechanical work.

Georgia's amendments to the IMC hand kitchen exhaust to the fire rules:

Roof Ceiling Exhaust fan on the roofPulls smoke and grease up and out Grease ductWelded, sealed, with cleanout doors HoodBaffle filters catch grease Grease cup at the end FryerGriddleRange Cooking line: heat, smoke and grease rise into the hood Makeup airFresh air comes back into replace what leaves Room air
How a hood system moves air: up through the filters and duct, out the roof fan, with makeup air coming back in.

The state fire rules

Rule 120-3-3 adopts NFPA 96, 2024 edition, effective May 27, 2025. The Georgia fire code changes add several lines that matter to a hood:

The suppression guide covers the licenses, tags and records for the extinguishing system. The hood cleaning guide covers upkeep.

A local company can take it from here. One form, free for restaurants.

Get connected

The health rules

DPH Rule 511-6-1-.05 says an exhaust hood system, including hoods, fans, guards and ducting, must prevent grease or condensation from dripping onto food, equipment or utensils. Grease filters or extracting equipment must be easy to remove for cleaning. The system must be sufficient in number and capacity to keep grease or condensation from collecting on walls and ceilings.

Rule .07 adds that if exhaust vents outside, the ventilation may not create a public health hazard or a nuisance. Intake and exhaust ducts are cleaned and filters changed so they are not a source of contamination.

When you submit a kitchen to the county health office for plan review, the packet includes mechanical plans and the type and model of fixed equipment, and the hood is on that list.

What a permit office asks for

Each city and county sets its own checklist.

In the City of Atlanta, applications go through the online permitting portal, and mechanical plans are required uploads. The city asks for the physical state-issued contractor license card for any permit and does not accept the Secretary of State's printout for electronic submissions. Every new application since February 1, 2026 uses the 2024 IMC. Atlanta's Office of Buildings can be reached at 404-330-6150.

In Gwinnett County, Planning and Development handles commercial construction, fire suppression system permits and mechanical, electrical and plumbing trade permits, all through the ZIP Portal. After plan review, fees and contractor details, the permit is issued to the contractor of record. Inspections need the permit case number.

Ask the building department which contractor license it requires for hood and duct work.

Before you buy a hood

  1. Does the plan call for a Type I hood, and does the local office agree?
  2. Where will the duct run, and does the fire marshal want access panels at certain points?
  3. How will makeup air be supplied?
  4. Is a fire-extinguishing system included, and is the installer licensed under Rule 120-3-23?
  5. Which edition of NFPA 96 will the inspector use at final?

On the last question, note that Georgia changed editions in 2025 and published more proposed changes later that year, so confirm the current text with your fire marshal.

Energy rebates

Georgia Power lists a commercial rebate for high-efficiency ventilation hoods with sensor control, at $500 per horsepower, on its rebates page. Eligibility is set in each program's rules, so read them before you buy.

Tell us about the new hood or exhaust upgrade in the form, and we'll connect you with one licensed contractor near your Georgia kitchen.

Questions

What building code covers a restaurant hood in Georgia?

The 2024 International Mechanical Code with Georgia amendments took effect January 1, 2026. Its kitchen exhaust sections point to NFPA 96 and NFPA 101 as adopted by the Safety Fire Commissioner.

Does a Georgia kitchen hood need fire suppression?

Yes. The Georgia fire code changes require each required commercial kitchen exhaust hood and duct system to have an approved automatic fire-extinguishing system.

Which NFPA 96 edition does Georgia use?

The 2024 edition, effective May 27, 2025. The earlier edition was 2017.

Can I use a home range in a commercial kitchen?

Georgia's mechanical amendments apply NFPA 101 and NFPA 96 to commercial installations of domestic cooking systems, so the commercial hood rules reach them.

Sources

  1. DCA 2026 code changes memo
  2. DCA 2026 IMC amendment packet
  3. Georgia Rule 120-3-3, State Minimum Fire Safety Standards (OCI PDF)
  4. Georgia Rule 120-3-3-.04, adopted standards and history
  5. Georgia Rule 511-6-1-.05, exhaust hoods
  6. Georgia Rule 511-6-1-.07, ventilation
  7. City of Atlanta construction codes
  8. City of Atlanta online permitting
  9. Gwinnett County building services
  10. Georgia Power commercial rebates
  11. OCI proposed rule notice, Nov 6, 2025